IDEC

Search Results For 'HR1S'

Showing 1 - 10 of 10 Products

HR1S-AC5121

Safety Control Relay 22mm PLe Category 3 24VDC; NC input contact type E-Stop/ Safety Switch; 3NO relay safety output; 1 NO monitor transistor output

HR1S-AC5121P

Safety Control Relay 22mm PLe Cat 3 24VDC; NC input contact type E-Stop/Safety Switch; 3NO relay output; 1 NO aux transistor output; removable block

HR1S-AF5130B

Safety Control Relay 22mm PLe Category 4 24VDC; 1-Dual Channel Input for NC contact type E-Stop or Safety Switch; 3NO relay safety output

HR1S-AF5130PB

Safety Control Relay 22mm PLe Category 4 24VDC; NC input contact type E-Stop/Safety Switch; 3NO relay safety output; removable terminal block

HR1S-ATE5110

Safety Control Relay 45mm Dual Channel PLe Cat 4; 2NO Instant + 3NO time delay safety output; 4 transistor monitor outputs 24VAC/DC

HR1S-ATE5110P

Safety Control Relay 45mm Dual Channel PLe Cat 4; 2NO Instant + 3NO time delay safety output; 4 transistor monitor outputs 24VAC/DC Removable Block

HR1S-DMB1132

Safety Control Relay 22mm PLe Cat 4 24VDC; 2 Inputs 1NO-1NC Non Contact Safety Switch; 2NO relay safety output; 2NO aux transistor output

HR1S-DMB1132P

Safety Control Relay 22mm PLe Cat 4 24VDC; 2 Inputs 1NO-1NC Non Contact Safety Switch; 2NO relay output; 2NO aux transistor output; removable block

HR1S-DME1132

Safety Control Relay 22mm PLe Cat 4 24VDC; 6 Inputs 1NO-1NC Non Contact Safety Switch; 2NO relay safety output; 2NO aux transistor output

HR1S-DME1132P

Safety Control Relay 22mm PLe Cat 4 24VDC; 6 Inputs 1NO-1NC Non Contact Safety Switch; 2NO relay output; 2NO aux transistor output; removable block

Found 1 match(es) for HR1S

HR1S Series

HR1S safety control relays are compact units designed to monitor safety input devices, which allow machine operation only when all safety controls are functioning properly and hazardous conditions are not detected. Supported safety devices include E-Stops, interlock switches and non-contact safety switches. These relays have either instantaneous (STOP 0) or time delayed (STOP 1) relay safety outputs, as well as solid-state outputs for use with diagnostics, troubleshooting and correct system operation. In addition, front panel LEDs can be used for monitoring the current status and most models are available in a variety of monitoring configurations, including removable terminals, monitored start, and single- or dual-channel operation.

The HR1S series of safety control relays provide increased functionality when designing equipment to meet global safety requirements in the U.S. and Europe, while adhering to EN ISO 13849-1 PLe, Safety Cat 4 and EN 62061 SIL 3.